PDFY-P WM-E


Achieving creative air conditioning design
through a rich array of system materials.



Flexible installation for a variety of layouts


Air outlet side compatible with a variety of ducts (optional)


Adjustable setting of external static pressure to meet system configuration and installation conditions


Static pressure settings can be increased to adjust to all kinds of ducts as well as functional upgrade option (high performance filter etc). An increase from the standard 50Pa to 130 Pa is possible to cope with various layout configurations.
*For P100-P125


Slim 295mm main unit with optional drain up mechanism ensures up to 600mm* of lift




Multiple installation patterns for assorted applications and locations



click image to enlarge

PEFY-P VML-E


Increased design flexibility for hotel and residential use
from an ultra thin body.




Low static pressure (5Pa) meets an application requiring direct air flow


Changeable air flow rate (3 stage low-middle-high)


Flexible installation by rear or bottom return air inlet.


Filter is attached as standard.



Ultra low height unit with 225mm* high

*: 8-7/8in.


Can be installed easily in tight spaces, such as ceiling cavities or drop-ceilings.

Notes: Drain lift-up pump not applicable.



click image to enlarge

Reduced noise thanks to the use of newly designed centrifugal fan


Noise level table (Standard static pressure 220V)


Note: In the case of bottom inlet, the operating noise is louder than in the case of rear inlet.


Drainage lines may be connected on either the right or left side.


Perfect for use in hotels and other places where line placement is a problem.



PEFY-P VMH-E


Increased design flexibility from sufficient external static pressure allow authentic duct air-conditioning with an elegant interior layout.



Maximum external static pressure 200pa


The additional external static pressure capacity provides flexibility for duct extension, branching and air outlet configuration.



Reduced noise thanks to the use of newly designed centrifugal fan


Noise level table (Standard static pressure 220V)


One-side maintenance


All maintenance to the unit, including fan inspection and fan motor removal, can be conducted from the inspection opening on one side.



Drain up mechanism (option) ensures up to 550mm* of lift


*: 21-11/16in.


The introduction of an upper drain mechanism allows the drain connection to be raised as high as 550mm*, allowing more freedom in piping layout design and reducing horizontal piping requirements.



click image to enlarge